RAVR040

RAVR0402018-10-21T19:59:56+08:00

Project Description

RAVR040

• 1 A Contact
• Rated current: 40 A
• Sealed structure, no arc leaks
• Can cut off up to 1000 V DC by magnetic quenching
• Filled with reducing gas, high reliability and stable
Coil data
Rated voltage12 / 24 V DC
Rated power3 W
Max. voltage16 / 32 V DC
Response voltage≤ 9 / 18 V DC
Drop out voltage≥ 1 / 2 V DC
Coil resistance48 / 192 Ω
Holding current0.25 / 0.125 A
Operating time≤ 30 ms
Release time≤ 10 ms
Bounce time≤ 5 ms
Contact data
Contact configuration1 A
Contact materialCu alloy
Max. continuous current40 A
Max. switching rating1000 V DC, 400 A (300 V DC), 120 KW
Rated contact voltage450 V DC
Overload cutoff750 V DC 120 A 50 Ops
Reverse cutoff-40 A 200 V DC 1000 Ops
Min. load1 A  12 V DC
Short-time current60 A 15 min, 100 A 2 min. (≥ 10 mm2)
Contact resistance≤ 10 mΩ (6 V DC 20 A)
Mechanical life2×105 times
Electrical life450 V 1×104 times
750 V 3×103 times
General data
Rated withstand voltage (Between contacts)2500 V AC 60 Sec. 10 mA
Rated withstand voltage (Coil / Contact)4000 V AC 60 Sec. 10 mA
Surge voltage5000 V AC
Insulation resistance100 MΩ (500 V DC)
Electrical clearance> 10 mm
Creepage distance> 10 mm
VibrationFunctional test, 49 m/s2 10~200 Hz, (10 µs)
Destructive test, 49 m/s2 10~200 Hz 4 h
ShockFunctional test, 196 m/s2 11 ms, (10 µs)
Destructive test, 490 m/s2 6 ms
Ambient temperature (Operation)-40~85 ℃ (No condensation)
Operating humidity5~85%
Dimension L×W×H (mm)72×32.6×57.7
Weight (g)180
Model designationContact loadAuxiliary contactContact configurationCoil voltageCoil terminationSpecial code
RAVR040-112D1
RAVR:
Square type
020: 20ABlank: Without
auxiliary contact
-1: 1 A12: 12VDCD: Wire lead,
without fast terminal
01~99
040: 40A24: 24VDCE: Wire lead,
with fast terminal
100: 100A
120: 120A
150:150A
200:200A