Project Description

RH-1P
• 1 Form A• Rated current: 30 A
• Small and high-power
• AC/DC Input voltage
![]()
| Coil data | |
|---|---|
| Coil input voltage | 6/12/24/48/100 V DC, 12/24/50/110/220 V AC |
| Coil power | D Type: 1,900 mW, A Type: 1.7~2.5 VA |
| Response voltage | < 75% (Room temp.) |
| Drop out voltage | > 5% (Room temp.) |
| Operation time / Release time | Less than 30 ms / less than 30 ms |
| Contact data | |
| Contact numbers | 1 Form A |
| Contact material | Ag alloy |
| Max. switching voltage | 220 V AC |
| Max. swiching power | 6,600 VA |
| Contact ratings | 30 A 220 V AC |
| Contact resistence | Max. 50 mΩ (1 A / 6 V DC) |
| Mechanical service life | 1×107 times |
| Electrical Service life (AC1) | 5×104 times |
| General data | |
| Rated withstand impulse voltage (Coil / Contact) | 4 kV AC / 1 min |
| Rated withstand impulse voltage (Between contacts) | 2 kV AC / 1 min |
| Surge voltage | 2 kV AC / 1 min |
| Insulation Resistance | 1,000 MΩ (500 V DC) |
| Vibration | Malfunction 10~55 Hz (Amplitude 1.5 mm) |
| Endurance 10~55 Hz (Amplitude 1.5 mm) | |
| Shock | Malfunction 98 m/s2, Endurance 980 m/s2 |
| Ambient temperature (Operation) | -25~60 ℃ (No condensation) |
| Operating humidity | 20~85% |
| Dimension L×W×H (mm) | 50.5×33.5×36 |
| Enclosure type | Dust cover |
| Mounting | PCB & faston terminal & flange type |
| Weight (g) | 93 |
| Compliance certification number | cULus:E341569 |
| Model designation | Number of poles | Coil voltage | Coil type | Contact configuration | Terminal Shape | Installation Mode | Special request |
| RH | -2 | 12 | D | M | P | 1 | -XXX |
| RH | 1: 1 pole | DC: 6, 12, 24, 48, 100 | D: DC | M: Form A | Blank: Faston terminal | 1: Standard | |
| 2: 2 poles | AC: 12, 24, 50, 110, 220 | A: AC | P: PCB | 2: Flange | |||
| Product manual - General Relay | Version 4.0 | 28 MB |
| RH | Version 3.0 | 1,014 KB |